The DOI matches its Crossref record.
Effective Dose Equivalent on the Ninth Shuttle–Mir Mission (STS-91)
Abstract
Organ and tissue doses and effective dose equivalent were measured using a life-size human phantom on the ninth Shuttle-Mir Mission (STS-91, June 1998), a 9.8-day spaceflight at low-Earth orbit (about 400 km in altitude and 51.65 degrees in inclination). The doses were measured at 59 positions using a combination of thermoluminescent dosimeters of Mg(2)SiO(4):Tb (TDMS) and plastic nuclear track detectors (PNTD). In correcting the change in efficiency of the TDMS, it was assumed that reduction of efficiency is attributed predominantly to HZE particles with energy greater than 100 MeV nucleon(-1). A conservative calibration curve was chosen for determining LET from the PNTD track-formation sensitivities. The organ and tissue absorbed doses during the mission ranged from 1.7 to 2.7 mGy and varied by a factor of 1.6. The dose equivalent ranged from 3.4 to 5.2 mSv and varied by a factor of 1.5 on the basis of the dependence of Q on LET in the 1990 recommendations of the ICRP. The effective quality factor (Q(e)) varied from 1.7 to 2.4. The dose equivalents for several radiation-sensitive organs, such as the stomach, lung, gonad and breast, were not significantly different from the skin dose equivalent (H(skin)). The effective dose equivalent was evaluated as 4.1 mSv, which was about 90% of the H(skin).
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Among these studies, MARE is the first experiment to measure the effect of wearable shielding on the deposition of radiation dose within a human phantom in space, as well as the first experiment in general to map the dose deposition within anthropomorphic phantoms beyond LEO.”
From First evaluation of wearable radiation protection for human deep space exploration, as flown on Artemis I (2026) · cites this paper as [19]
In the citing paper
“Among these studies, MARE is the first experiment to measure the effect of wearable shielding on the deposition of radiation dose within a human phantom in space, as well as the first experiment in general to map the dose deposition within anthropomorphic phantoms beyond LEO.”
From First evaluation of wearable radiation protection for human deep space exploration, as flown on Artemis I (2026) · cites this paper as [19]
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 24
- 10.1016/1359-0189(92)90084-9 · DOI · Paper page
- 10.1016/0273-1177(94)90495-2 · DOI
- W. Hoffman, and B. Prediger .Heavy particle dosimetry with high temperature peaks of CaF 2 :Tm and 7 LiF phosphors., Radiat. Prot. Dosim, 6 :149 –152 .1984 . · DOI
- N. Vana, W. Schoner, M. Fugger, and Y. Akatov .Absorbed dose measurement and LET determination with TLDs in space., Radiat. Prot. Dosim, 66 :145 –152 .1996 . · DOI
- O. B. Geiß, M. Krämer, and G. Kraft .Efficiency of thermoluminescent detectors to heavy charged particles., Nucl. Instrum. Methods, B142 :592 –598 .1998 . · DOI
- 10.1088/0022-3727/32/10/315 · DOI
- 10.1016/1350-4487(94)00084-E · DOI
- 10.1016/S1350-4487(96)00095-9 · DOI
- 10.2187/bss.11.355 · DOI
- 10.2307/3578867 · DOI
- 10.1016/0969-8078(93)90167-3 · DOI
- 10.1146/annurev.ns.33.120183.001543 · DOI · Paper page
- H. Yasuda, and K. Fujitaka .Responses of TLD-Mg 2 SiO 4 :Tb and radiophoto-luminescent glass to heavy charged particles and space radiation., Radiat. Prot. Dosim, 87 :115 –120 .2000 . · DOI
- 10.1016/0020-708X(82)90237-X · DOI
- 10.1088/0022-3727/21/5/022 · DOI
- P. Olko, P. Bilski, and V. M. Michalik .Microdosimetric analysis of the response of LiF thermoluminescent detectors for radiations of different qualities., Radiat. Prot. Dosim, 52 :405 –408 .1994 . · DOI
- O. B. Geiß, M. Krämer, and G. Kraft .Verification of heavy ion dose distributions using thermoluminescent detectors., Nucl. Instrum. Methods, B148 :541 –544 .1998 . · DOI
- 10.1016/S1350-4487(97)00118-2 · DOI
- H. Yasuda, Incident-angle dependency found in track formation sensitivity of a plastic nuclear track detector (TD-1)., J. Health Phys, 34 :387 –190 .1999 . · DOI
- 10.1016/1350-4487(95)00291-X · DOI
- 10.2307/3578496 · DOI
- 10.1016/1359-0189(92)90082-7 · DOI
- 10.2307/3577902 · DOI
- 10.1016/0273-1177(96)00034-8 · DOI
Cited by
Sorted by citations
ICRP Publication 123: Assessment of Radiation Exposure of Astronauts in Space
Dietze, G., Bartlett, D. T., Cool, D. A., Cucinotta, F. A., Jia, X., McAulay, I. R., Pelliccioni, M., Petrov, V., Reitz, G., & Sato, T. (2013) · Annals of the ICRP · doi:10.1016/j.icrp.2013.05.004 · Cited by 239
Physical and biological organ dosimetry analysis for international space station astronauts
Cucinotta, F. A., Kim, M.-H. Y., Willingham, V., & George, K. A. (2008) · Radiation Research · doi:10.1667/rr1330.1 · Cited by 196
Reitz, G., Berger, T., Bilski, P., Facius, R., Hajek, M., Petrov, V., Puchalska, M., Zhou, D., Bossler, J., Akatov, Y., et al. (2009) · Radiation Research · doi:10.1667/rr1559.1 · Cited by 128
Chromosome aberrations in the blood lymphocytes of astronauts after space flight
George, K., Durante, M., Wu, H., Willingham, V., Badhwar, G., & Cucinotta, F. A. (2001) · Radiation Research · doi:10.1667/0033-7587(2001)156[0731:caitbl]2.0.co;2 · Cited by 119
Self-citationDurante, M. (2002) · La Rivista del Nuovo Cimento · doi:10.1007/bf03548911 · Cited by 38
Metadata
- Authors
- Yasuda, H., Badhwar, G. D., Komiyama, T., & Fujitaka, K.
- Affiliations
- Johnson Space Center (US)
- Japan Aerospace Exploration Agency (JP)
- National Institute of Radiological Sciences (JP)
- Corresponding author
- Yasuda, Hiroshi
- Venue
- Radiation Research
- Publisher
- Radiation Research Society
- Published
- 2000-12
- Volume
- 154
- Issue
- 6
- Pages
- 705-713
- ISSN
- 0033-7587 (ISSN-L)
- 1938-5404
- OpenAlex
- W2205206171
- Cited by
- 56
- References
- 0
- Citations by year
- 2026: 1 · 2022: 1 · 2021: 1 · 2020: 1 · 2019: 1 · 2016: 3 · 2015: 2 · 2014: 2 · 2013: 4 · 2012: 5
- FWCI
- 3.59
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Radiation Research (publishedVersion)
- PubMed (publishedVersion)
- BioOne Complete (BioOne) (submittedVersion)
- Topics
- Physical Sciences › Physics and Astronomy › Radiation › Radiation Therapy and Dosimetry
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
- Health Sciences › Medicine › Physiology (medical) › Spaceflight effects on biology
- Keywords
- effective dose equivalent, STS-91, space radiation, low Earth orbit, HZE particles, LET, quality factor, thermoluminescent dosimeters, plastic nuclear track detectors, human phantom, radiation protection
- MeSH terms
- Calibration, Cosmic Radiation, Humans, Models, Theoretical, Organ Specificity, Radiation Dosage, Radiation Monitoring, Space Flight, Phantoms, Imaging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review